Screen refresh problem [1]

Screen refresh problem

Monday, June 10, 2002 12:54 PM - ryan

Hi Sir,

I got a problem while using Xmanager on windows 2000.
When I open a GUI (graphic user interface) like synopsys DC, the frame of this GUI will lose after running other works. The part occluded cannot be shown correctly until we refresh the window manually. Even if we change the backing store as Always, this situation cannot be improved. Would you have any ideas? or Any options have to be made.

Best regards,

Ryan


Re: Screen refresh problem

Monday, June 10, 2002 1:35 PM - Support

Window frame can be fixed by choosing "Local Only" in the "Window Manager" list box of Xconfig. After changing the option, close Xconfig and run Xmanager again.

Also, the following options are recommended:

Backing Store: WhenMapped
Default Visual: PseudoColor

Please let us know if the problem persists.

----
Technical Support


Previous views: 147